This is an old revision of the document!


QC1 on Geonor bucket content RA

Applies to equipmenttypeid=7 and equipmentmodel like 'GEONOR%'.

Every sensor will have one entry in table checks with

  • stationid=sensor_info.stationid
  • qcx=QC1-1-104
  • medium_qcx=QC1-1
  • checkname=RANGE_CHECK
  • checksignature=obs;RA;;|meta;RA_max,RA_highest,RA_high,RA_low,RA_lowest,RA_min;;

and one corresponding row in table station_param

  • qcx=QC1-1-104
  • metadata=max;highest;high;low;lowest;min: <a>;<b>;<b>;-3.0;-3.0;-3.0 where <a>, <b>, and <b> is equipmentmodel specific.
    • GEONOR T200 : <a> = 615, <b> = 500
    • GEONOR T200B : <a> = 615, <b> = 500
    • GEONOR T200BM : <a> = 1100, <b> = 900
    • GEONOR T200BMD : <a> = 1600, <b> = 1400