QC1 on Geonor bucket content RA

Applies to sensor_info.measurement_methodid=217502 and equipmentmodel.description starts with an integer <V>.

Every sensor will have one entry in table checks with

  • stationid=sensor_info.stationid
  • qcx=QC1-1-104
  • medium_qcx=QC1-1
  • checkname=RANGE_CHECK
  • checksignature=obs;RA;;|meta;RA_max,RA_highest,RA_high,RA_low,RA_lowest,RA_min;;

and one corresponding row in table station_param

  • qcx=QC1-1-104
  • metadata=max;highest;high;low;lowest;min: <V>+115;<V>;<V>;50.0;0.0;-3.0
This website uses cookies. By using the website, you agree with storing cookies on your computer. Also you acknowledge that you have read and understand our Privacy Policy. If you do not agree leave the website.More information about cookies
  • kvalobs/kvalobs/qc1-1_on_geonor_bucket_content.txt
  • Last modified: 2022-05-31 09:29:32