This is an old revision of the document!


Redistribution of 24 hour precipitation

RR_24 is the precipitation collected over the last 24 hours. The Qc1 check precipcollected_flag identifies if an RR_24 value is valid (fd=1), erroneous (fd=3) or is the accumulation (fd=2) of a number (N) of consecutive 24 hour periods, where N>1. For the case fd=2, the accumulated value shall be distributed over the N 24 hours periods.

For each day the calculated

RR_24= model_value*observed_accumulation/sum_of_model_values

where the model values for the N missing values of RR_24 are calculated by an interpolation from the other stations making measurements at the same time and for which fd=1. At present, the interpolation uses an inverse 2-D squared distance weighting. Other weighting and interpolation techniques might be added later.

The calculated RR_24 updates the corrected value in the kvalobs database.

The standard configuration options detailed in the user guide also apply to Redistribution.

Further configuration options are:

  • endpoint_cflags (default: fmis=4&fd=2) and endpoint_uflags (default: no constraints) specify the flags for accumulation endpoints. Endpoints not matching these flags will not be detected.
  • missingpoint_cflags (default: fmis=3&fd=2) and missingpoint_uflags (default: no constraints) specify the flags for the missing points before the accumulation.
  • neighbor_cflags (default: fd=1) and neighbor_uflags (default: U2=0) specify requirements for the neighbor stations used for the interpolations. Neighbor stations that do not match these flags will be ignored.
  • warn_and_stop_cflags (default: fhqc=)0() and warn_and_stop_uflags (default: no constraints) define for which flags for the accumulation point or the missing points before the accumulation the only action should be to print a warning and stop.
  • update_flagchange (default: fd=7;fmis=3→fmis=1;fmis=0→fmis=4) flags to change for the accumulation endpoint and the missing points.
  • ParamId (no default) selects the parameter ids to use. The only value tested here is 110 (RR_24).
  • tids accepted typeids
  • measurement_hour (default: 6) specifies the hour at which the data are expected. Series containing data with other times will be rejected with a warning.

This algorithm has only been tested for paramid 110.

This website uses cookies. By using the website, you agree with storing cookies on your computer. Also you acknowledge that you have read and understand our Privacy Policy. If you do not agree leave the website.More information about cookies
  • kvalobs/kvoss/system/qc2/requirements/algorithms/rarr_24.1323173279.txt.gz
  • Last modified: 2022-05-31 09:23:18
  • (external edit)