This is an old revision of the document!
Temporal interpolation for "one-point" gaps in hourly temperature
Description of Method
- Locate a single missing value
- Check if data available immediately before and after the interval
- If available generates first estimate from linear interpolation
- Checks for the Max and Min temperature for the missing value from the measurements registered in the hour afterwards
- Provide an estimate T1 for the missing value as the average of 0.5*(MaxT + MinT)
- Update the correcte dvalue following the rules below:
If an existing corrected value exists and it was generated by HQC:
- do not update, leave correction from HQC
If an existing corrected value exists and not from HQC:
- check if existing value: MaxT >= existing corrected >= MinT
- if FALSE update corrected with T1
If no corrected value exists:
- update corrected value with T1
Quality Control Level
- …
Run Parameters
It shall be possible to run the algorithm for
- …
- …
- …
Characteristics of the data to which the method is applied
CONTROLINFO AND/OR USEINFO
- …
TYPEID, PARAMIDS, OTHER METADATA
- …
Flag Settings
SPECIFICATION OF CONTROLFLAGS TO BE SET FOR EXPECTED RESULTS OF THE ALGORITHM, I.E. CONSIDER BOTH POSITIVE AND NEGATIVE RESULTS
- …
EXPECTIONS OF THE USEINFO FLAGS CORRESPONDING TO CONTROLINFO FLAG SETTINGS
- …
Dependencies
- …
- …
- …