Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
kvalobs:kvalobs:qc17 [2022-05-31 09:29:32]
external edit
— (current)
Line 1: Line 1:
- 
-============ 
-|[[http://klima.dnmi.no/|KLIMA]]** **|[[http://instrument/obs/|OBSERVASJON]]** **|[[http://fou.dnmi.no/|FOU]]|[[http://it.dnmi.no/|IT]]| 
- 
-KVALOBS \\  Kvalitetssikring av observasjoner  
- 
- 
----- 
- 
-======QC1-7 DETECTION OF COLLECTED VALUES FOR SEPARATION====== 
-Gabriel Kielland  
- 
-In the extended use and presentation of some observations there is a need to infere a simulated observation taken to cover a shorter time span than the one observed.  
- 
-In Kvalobs the separation procedure will be implemented for precipitation, maximum temperature and minimum temperature.  
- 
-The Kvalobs parameters are:  
- 
-  *RR_X - Amount of precipitation which has fallen during a period preceding the standard time of observation;  
-  *TAX_X - Temperature in degrees C, maximum one minute value during a period preceding the standard time of observation;  
-  *TAN_X - Temperature in degrees C, minimum one minute value during a period preceding the standard time of observation.  
-The parameter values RR_X, TAX_X and TAN_X will be entered in the database together with values to indicate commencement and ending of the period. The time parameters are:  
- 
-  *KLSTART - Time of phenomenon commencement, 12 digits YYYYMMDDHHmm ("measurement from" 
-  *KLOBS - Time of phenomenon ending, 12 digits YYYYMMDDHHmm ("measurement untill" 
-The following flag values are available:  
- 
-|fd=0|Not considered as collected value| 
-|fd=1|Normal observation, not collected value| 
-|fd=2|The original value is a collected value not separated| 
-|fd=3|Abnormal observation. The original value may be a collected value| 
- 
- 
-====The rules for applying the flag values is the following:==== 
-"measurement from" minus "measurement untill" < 23 hours => fd=3  
- 
-"measurement from" minus "measurement untill" >= 23 hours og\\  "measurement from" minus "measurement untill" <= 25 hours => fd=1  
- 
-"measurement from" minus "measurement untill" > 25 hours og\\  "measurement from" minus "measurement untill" < 47 hours => fd=3  
- 
-"measurement from" minus "measurement untill" >= 47 hours og\\  "measurement from" minus "measurement untill" <= 73 hours => fd=2  
- 
-"measurement from" minus " measurement untill" > 73 hours => fd=3  
- 
-Note that whenever KLOBS or KLSTART is a non valid time indication the __observationen__ is flagged with fd=3.  
- 
-Also with KLOBS or KLSTART missing the observation is flagged with fd=3.  
- 
-  
- 
- 
-=====Automatic separation of precipitation amount===== 
-The separation algorithms is implemented in QC2 [[kvoss:system:qc2:requirements:algorithms:rarr_24|Redistribution]]. The observation stored as an RR_X parameter is translated into one or several RR_24 values. The observed value is kept in the field //data.original// and the separated partial values are placed in the fields //data.corrected// 
- 
- 
-Last modified: 2011-12-07 14:15:00 +0100 
- 
  
  • kvalobs/kvalobs/qc17.1653989372.txt.gz
  • Last modified: 2022-05-31 09:29:32
  • by