====== Kvalobs range control (QC1-1) on relative humidity (UU) ====== The distribution of all UU measurements follows a Poisson distribution with deviations in the upper and lower end. From the assumption that the deviations consist of error values mostly, the range control values is chosen. * UU less than 5% is rejected * UU between 5% and 10% is flagged as very suspicious (probably wrong) * UU between 10% and 15% is flagged as somewhat suspicious (probably correct) {{kvalobs:kvalobs:uu0-30.png|The lower end distribution of all relative humidity observations from met.no automatic weather stations}}